Biphasic model of lung deformations for Video-Assisted Thoracoscopic Surgery (VATS) - Inserm - Institut national de la santé et de la recherche médicale
Conference Papers Year : 2019

Biphasic model of lung deformations for Video-Assisted Thoracoscopic Surgery (VATS)

Abstract

Intraoperative localization of small, low-density or deep lung nodules during Video-Assisted Thoracoscopic Surgery (VATS) is a challenging task. Localization techniques used in current practice require an additional preoperative procedure that adds complexity to the intervention and might yield to clinical complications. Therefore, clinical practice may benefit from alternative, intraoperative localization methods. We propose a nonrigid registration approach for nodule lo-calization. Our method is based on a biomechanical model of the lung, where the lung parenchyma is represented as a biphasic medium. Preliminary results are promising, with target registration errors reduced from 28.39 mm to 9.86 mm in median, and to 3.68 mm for the nodule in particular.
Fichier principal
Vignette du fichier
alvarez-ISBI19.pdf (1.8 Mo) Télécharger le fichier
Origin Files produced by the author(s)
Loading...

Dates and versions

inserm-02121765 , version 1 (06-05-2019)

Identifiers

  • HAL Id : inserm-02121765 , version 1

Cite

Pablo Alvarez, Saramati Narasimhan, Simon Rouzé, Jean-Louis Dillenseger, Yohan Payan, et al.. Biphasic model of lung deformations for Video-Assisted Thoracoscopic Surgery (VATS). IEEE International Symposium on Biomedical Imaging (ISBI), Apr 2019, Venice, Italy. ⟨inserm-02121765⟩
2791 View
258 Download

Share

More