Comparison between 2D and 3D dosimetry protocols in 90Y-ibritumomab tiuxetan radioimmunotherapy of patients with non-Hodgkin's lymphoma. - Inserm - Institut national de la santé et de la recherche médicale
Article Dans Une Revue Cancer Biotherapy & Radiopharmaceuticals Année : 2008

Comparison between 2D and 3D dosimetry protocols in 90Y-ibritumomab tiuxetan radioimmunotherapy of patients with non-Hodgkin's lymphoma.

Résumé

We compared the radiation-absorbed dose obtained from a two dimensional (2D) protocol, based on planar whole-body (WB) scans and fixed reference organ masses with dose estimates, using a 3D single-photon emission computed tomography (SPECT) imaging protocol and patient-specific organ masses. METHODS: Six (6) patients with follicular non-Hodgkin's lymphoma underwent a computed tomography (CT) scan, 5 2D planar WB, and 5 SPECT scans between days 0 and 6 after the injection of (111)In-ibritumomab tiuxetan. The activity values in the liver, spleen, and kidneys were calculated from the 2D WB scans, and also from the 3D SPECT images reconstructed, using quantitative image processing. Absorbed doses after the administration of (90)Y-ibritumomab tiuxetan were calculated from the (111)In WB activity values combined with reference organ masses and also from the SPECT activity values and organ masses as estimated from the patient CT scan. To assess the quantitative accuracy of the WB and SPECT scans, an abdominal phantom was also studied. RESULTS: The differences between organ masses estimated from the patient CT and from the reference MIRD models were between -10% and +98%. Using the phantom, errors in organ and tumor activity estimates were between -86% and 10% for the WB protocol and between -43% and -6% for the SPECT protocol. Patient liver, spleen, and kidney activity values determined from SPECT were systematically less than those from the WB scans. Radiation-absorbed doses calculated with the 3D protocol were systematically lower than those calculated from the WB protocol (29%+/-26%, 73%+/-26%, and 33%+/-53% differences in the liver, spleen, and kidney, respectively), except in the kidneys of 2 patients and in the liver of 1 patient. CONCLUSIONS:Accounting for patient-specific organ mass and using SPECT activity quantification have both a great impact on estimated absorbed doses.
Fichier non déposé

Dates et versions

inserm-00467253 , version 1 (26-03-2010)

Identifiants

Citer

Karine Assié, Arnaud Dieudonné, Isabelle Gardin, Irène Buvat, Hervé Tilly, et al.. Comparison between 2D and 3D dosimetry protocols in 90Y-ibritumomab tiuxetan radioimmunotherapy of patients with non-Hodgkin's lymphoma.. Cancer Biotherapy & Radiopharmaceuticals, 2008, 23 (1), pp.53-64. ⟨10.1089/cbr.2007.372⟩. ⟨inserm-00467253⟩
124 Consultations
0 Téléchargements

Altmetric

Partager

More