Intraoperative and postoperative gamma detection of somatostatin receptors in bone-invasive en plaque meningiomas.
Résumé
OBJECTIVE: Scintigraphy with a radiolabeled somatostatin analog ((111)In-diethylenetriaminepenta-acetic acid octreotide) detects the somatostatin receptors that are found in vitro in all meningiomas. Previous studies have proved the benefit of radioimmunoguided surgery, with a hand-held gamma probe, for the assessment and removal of neuroendocrine tumors. We conducted a study to determine whether intraoperative radiodetection of somatostatin receptors is feasible and could increase the probability of complete meningioma resection, especially for bone-invasive en plaque meningiomas, which are difficult to control surgically. METHODS: Eighteen patients with en plaque sphenoid wing and cranial convexity meningiomas were studied by preoperative and postoperative somatostatin receptor scintigraphy. In 10 of them, intraoperative radiodetection with a hand-held gamma probe was performed 24 hours after the intravenous administration of (111)In-diethylenetriaminepenta-acetic acid octreotide. This procedure was combined with a computer-aided navigation system. RESULTS: All preoperative scintigrams were positive. Intraoperative gamma probe detection was achieved for the invaded bone, dura, and periorbit of sphenoid wing meningiomas. The average tumor/nontumor count ratio was 2:1, with a maximum of 12:1, thus allowing precise detection capable of defining the tumor margins. In three cases of sphenoid wing meningiomas, postoperative scintigrams were helpful for the determination of recurrences that magnetic resonance imaging failed to detect. CONCLUSION: These preliminary data show that intraoperative radiodetection of somatostatin receptors with a hand-held gamma probe is feasible and may be helpful to guide the surgical removal of bone-invasive en plaque meningiomas. Preoperative and postoperative scintigraphy may be useful for the management and follow-up of patients with these tumors.
Fichier principal
Patient_table_1_REVISION.pdf (27 Ko)
Télécharger le fichier
FIGURE_1.ppt (240.5 Ko)
Télécharger le fichier
Intraoperative_and_Postoperative_Gamma_Detection_of_REVISION.pdf (54.7 Ko)
Télécharger le fichier
figure_2.pdf (20.16 Ko)
Télécharger le fichier
figure_3_A.TIF (1.27 Mo)
Télécharger le fichier
figure_3_B.TIF (1.11 Mo)
Télécharger le fichier
figure_3_C.TIF (1.02 Mo)
Télécharger le fichier
figure_3_D.TIF (1.12 Mo)
Télécharger le fichier
figure_3_E.TIF (1.31 Mo)
Télécharger le fichier
figure_3_F.TIF (1.54 Mo)
Télécharger le fichier
inserm-00391007_edited.pdf (2.17 Mo)
Télécharger le fichier
Origine | Fichiers produits par l'(les) auteur(s) |
---|
Format | Autre |
---|
Origine | Fichiers produits par l'(les) auteur(s) |
---|
Origine | Fichiers produits par l'(les) auteur(s) |
---|
Format | Autre |
---|
Format | Autre |
---|
Format | Autre |
---|
Format | Autre |
---|
Format | Autre |
---|
Format | Autre |
---|
Origine | Fichiers produits par l'(les) auteur(s) |
---|